Heat Pump Repair in Ruston, LA
Homes here need heat from November through March and cooling from May through September. If your system quits, tell us what it's doing and a licensed contractor who covers Lincoln Parish will get in touch.
Tell us about the job
It takes about a minute.
Ruston asks a lot of your heat pump, both ways
Your heat pump works ten months a year in Ruston, heating from November through March and cooling from May through September. That leaves little downtime for the compressor or the outdoor coil to rest and recover between seasons.
Winter nights averaging 37°F mean the system runs a defrost cycle on and off to keep the outdoor coil clear of ice. Over a season that adds up to a lot of cycling, and the reversing valve that switches the unit between heating and cooling takes the wear. Summer afternoons near 92°F push the compressor hard on the cooling side. And with 51 damaging wind events recorded in Lincoln Parish over the past ten years, the outdoor unit and its electrical connections take a beating too. If the power has cut out during a storm, most heat pumps come back on by themselves once it returns, but a unit that will not restart after an outage is worth a call.
- 5 months
- November through March, your system heats
- 5 months
- May through September, it cools
- 37°F
- the average winter night it heats against
- 92°F
- the average summer afternoon it cools against

NOAA nClimDiv, 1991–2020 normals
Louisiana requires HVAC contractors to hold a state license.
The Louisiana State Licensing Board for Contractors tests contractors before they can hold this license, and it keeps a record of who holds one. That license attaches to the contractor, not to any single job, so the same credential that qualifies them for a heat pump repair in Lincoln Parish covers their work across the state.
A heat pump moves refrigerant, and opening that side of the system takes something beyond the state license. Federal law requires EPA Section 608 certification for that work, in Louisiana and every other state. Between the two, the contractor working on your heat pump answers to a state board that licensed them and a federal rule that certified them for the refrigerant itself.
Source: Louisiana State Licensing Board for Contractors
- Why is my heat pump blowing cold air?
- In heating mode, a heat pump puts out air that feels cooler than a furnace does, usually around body temperature, and that can feel cold blowing on your skin even when it's working right. If the air is actually cold, not just lukewarm, check that the outdoor unit isn't iced over or blocked by leaves and debris. A thermostat set to "emergency heat" also skips the heat pump and can leave you feeling a cold draft while backup heat catches up. If the outdoor unit is running and you still get cold air at the vents, that points to a refrigerant or compressor problem, and only a licensed contractor with EPA 608 certification can open the refrigerant side to find it.
- Why is there ice on my heat pump?
- Some frost on the outdoor coil during cold weather is normal. Your heat pump has a defrost cycle built in that melts it off every so often, usually running the fan in reverse for a few minutes. A heavy, solid buildup of ice is different. That usually means airflow is blocked, either by leaves and debris around the unit or a dirty coil, or the defrost control itself has failed. With winter nights here averaging 37°F, the unit is cycling through defrost often, so a control that's stuck or failing shows up fast as ice that never clears. Don't chip at the ice yourself. Turn the unit off and have a licensed contractor look at the defrost board and refrigerant charge.
- Why is my heat pump running but not cooling?
- If the outdoor unit and indoor fan are both running but the air coming out isn't cool, the most common cause is low refrigerant from a leak. A dirty outdoor coil or a blocked filter can also choke off enough airflow that the system can't pull heat out of your home the way it should, especially on a 92°F afternoon when it's already working hard. Check the filter first since that's something you can do yourself. If the filter is clean and the coil looks clear, the problem is inside the refrigerant system, and only a contractor holding EPA Section 608 certification is allowed to open it up and find the leak or check the charge.